<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Sensori volumetrici su BUS Archivi - AVS Electronics</title>
	<atom:link href="https://avselectronics.sviluppo.spherica.it/family/sensori-da-interno/sensori-volumetrici-su-bus/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description>Sicuri e protetti. Sempre.</description>
	<lastBuildDate>Thu, 12 Mar 2026 11:05:53 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://avselectronics.sviluppo.spherica.it/wp-content/uploads/2025/07/AVS_icona-150x150.png</url>
	<title>Sensori volumetrici su BUS Archivi - AVS Electronics</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>JET DT HP</title>
		<link>https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp/</link>
					<comments>https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp/#respond</comments>
		
		<dc:creator><![CDATA[Federico Spherica De Megni]]></dc:creator>
		<pubDate>Tue, 03 Mar 2026 14:47:58 +0000</pubDate>
				<guid isPermaLink="false">https://avselectronics.sviluppo.spherica.it/products/%family%/jet-dt-hp/</guid>

					<description><![CDATA[<p>&#8211; Infrarosso Passivo + Microonda&#8211; Portata 15 m&#8211; Lente di Fresnel asferica angolo di copertura 90° 7 piani e 41 settori, ottica sigillata&#8211; Lente Look-down a specchio per copertura anti-strisciamento&#8211; PET IMMUNE&#8211; Collegamento in seriale RS485&#8211; ANTIACCECAMENTO con IR attivo&#8211; Funzione Microonda:ANTIMASCHERAMENTO e controllo guasto&#8211; Funzione di test attivo infrarosso con segnalazione di guasto&#8211; Funzione [&#8230;]</p>
<p>L'articolo <a href="https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp/">JET DT HP</a> proviene da <a href="https://avselectronics.sviluppo.spherica.it">AVS Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&#8211; Infrarosso Passivo + Microonda<br />&#8211; Portata 15 m<br />&#8211; Lente di Fresnel asferica angolo di copertura 90° 7 piani e 41 settori, ottica sigillata<br />&#8211; Lente Look-down a specchio per copertura anti-strisciamento<br />&#8211; PET IMMUNE<br />&#8211; Collegamento in seriale RS485<br />&#8211; ANTIACCECAMENTO con IR attivo<br />&#8211; Funzione Microonda:ANTIMASCHERAMENTO e controllo guasto<br />&#8211; Funzione di test attivo infrarosso con segnalazione di guasto<br />&#8211; Funzione Security: automatica in caso di guasto IR o MW<br />&#8211; Funzione oscilloscopio e settaggio parametri con software XWIN<br />&#8211; Logica di funzionamento AND/OR/SECURITY<br />&#8211; Frequenza microonda: 10,525 GHz<br />&#8211; Memoria eventi con memorizzazione data ora, temperatura, segnali IR e MW<br />&#8211; Accelerometro per segnalazione apertura contenitore, strappo e disorientamento<br />&#8211; Ingresso AUX per collegamento tamper ANTISTRAPPO<br />&#8211; LED disattivabili<br />&#8211; Altezza di installazione: standard a 2,20 m &#8211; max. 2,70 m<br />&#8211; Assorbimento 60 mA max.<br />&#8211; Alimentazione 13.8 Vdc<br />&#8211; Condizioni ambientali: -20°C + 55°C<br />&#8211; Dimensioni (PxLxH): 65 x 120 x 39 mm</p>
<p>L'articolo <a href="https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp/">JET DT HP</a> proviene da <a href="https://avselectronics.sviluppo.spherica.it">AVS Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>JET DT HP PLUS</title>
		<link>https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp-plus/</link>
					<comments>https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp-plus/#respond</comments>
		
		<dc:creator><![CDATA[Federico Spherica De Megni]]></dc:creator>
		<pubDate>Tue, 03 Mar 2026 14:47:58 +0000</pubDate>
				<guid isPermaLink="false">https://avselectronics.sviluppo.spherica.it/products/%family%/jet-dt-hp-plus/</guid>

					<description><![CDATA[<p>&#8211; Infrarosso Passivo + Microonda &#8211; Portata 15 m &#8211; Lente di Fresnel asferica angolo di copertura 90° 7 piani e 41 settori, ottica sigillata &#8211; Lente Look-down a specchio per copertura anti-strisciamento &#8211; PET IMMUNE &#8211; Funzione oscilloscopio tramite software XWIN &#8211; Logica di funzionamento AND &#8211; Frequenza microonda:10,525 GHz &#8211; Ingresso AUX per [&#8230;]</p>
<p>L'articolo <a href="https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp-plus/">JET DT HP PLUS</a> proviene da <a href="https://avselectronics.sviluppo.spherica.it">AVS Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&#8211; Infrarosso Passivo + Microonda<br />
&#8211; Portata 15 m<br />
&#8211; Lente di Fresnel asferica angolo di copertura 90° 7 piani e 41 settori, ottica sigillata<br />
&#8211; Lente Look-down a specchio per copertura anti-strisciamento<br />
&#8211; PET IMMUNE<br />
&#8211; Funzione oscilloscopio tramite software XWIN<br />
&#8211; Logica di funzionamento AND<br />
&#8211; Frequenza microonda:10,525 GHz<br />
&#8211; Ingresso AUX per collegamento tamper ANTISTRAPPO<br />
&#8211; LED disattivabili<br />
&#8211; Collegamento in seriale RS485<br />
&#8211; Altezza di installazione: standard a 2,20 m &#8211; max. 2,70 m<br />
&#8211; Assorbimento 51 mA max.<br />
&#8211; Alimentazione 13.8 Vdc<br />
&#8211; Condizioni ambientali: -20°C + 55°C<br />
&#8211; Dimensioni (PxLxH): 65 x 120 x 39 mm</p>
<p>L'articolo <a href="https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp-plus/">JET DT HP PLUS</a> proviene da <a href="https://avselectronics.sviluppo.spherica.it">AVS Electronics</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://avselectronics.sviluppo.spherica.it/products/sensori-da-interno/sensori-volumetrici-su-bus/jet-dt-hp-plus/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
